LSZH (Thermoplastic) |
T7001 |
Outdoor optical fiber cable, data cable, and FTTH cable insulation and jacketing (OI:30) |
YD/T 1113-2015, IEC 60332-1-2 |
|
LSZH (Thermoplastic) |
T7001D |
Data cable, drop cable (simplex cable & duplex cable) and coaxial cable jacketing (OI:30) |
YD/T 1113-2015, YD/T 1997.1-2014, IEC 60332-1-2 |
|
LSZH (Thermoplastic) |
T7001E |
Outdoor optical fiber cable, data cable, and FTTH cable jacketing (OI:30) |
YD/T 1113-2015, YD/T 1997.1-2014, IEC 60332-1-2 |
|
LSZH (Thermoplastic) |
T7001F |
90°C Halogen-free low smoke flame-retardant tight buffer optical fiber compound |
/ |
|
LSZH (Thermoplastic) |
T7002A |
Date cable jacketing (OI:36) |
YD / T 1113-2015, IEC 60332-1-2, EN 50399 |
|
LSZH (Thermoplastic) |
T7002B |
Outdoor optical fiber cable, data cable, and FTTH cable jacketing (OI:30) |
YD / T 1113-2015, YD / T 1997.1-2014, IEC 60332-1-2 |
|
LSZH (Thermoplastic) |
T10016J |
EN power cord insulation |
HD 21.14 |
|
LSZH (Thermoplastic) |
T10016H |
EN power cord jacketing |
HD 21.14 |
|
LSZH (Thermoplastic) |
T10019 |
FR PE cable, high extrusion speed |
/ |
|
LSZH (Thermoplastic) |
T10020 |
PE cable, heat resistance, smooth extrusion surface |
/ |
|
LSZH (Thermoplastic) |
T10035H |
High FR LSOH jacketing (CAT A combustion) |
IEC 60332-3-22A |
|
LSZH (Thermoplastic) |
T10035J |
High FR LSOH insulation (small wire VW-1) |
VW-1, IEC 60332-1 |
|
XLPO (Silane Cross-linkable) |
XPS2251 |
Flexible cable insulation and jacketing, Density: 1.40, Smoke density(with flame): 80 |
/ |
|
XLPO (Silane Cross-linkable) |
XPS3251F |
Photovoltaic cable insulation and jacketing |
EN 50618-2004 |
|
XLPO (Silane Cross-linkable) |
XPS3251H-1 |
Photovoltaic cable jacketing |
EN 50618-2014, TUV 2PfG 1169, IEC 62930-2017 |
|
XLPO (Silane Cross-linkable) |
YD-125HPV |
Photovoltaic cable jacketing |
EN 50618, 2 PFG 1169/08.07 |
|
XLPO (Silane Cross-linkable) |
YD-125JPV |
Photovoltaic cable insulation |
EN 50618, 2 PFG 1169/08.07 |
|
XLPO (Silane Cross-linkable) |
XPS4000N |
Oil-resistant MV/HV cable, control cable, outdoor CT cable insulation SHF2 |
IEC 60092, 360 HF90 |
|
XLPO (Silane Cross-linkable) |
XPS5501N |
150°C HV wire in automotive insulation and jacketing |
ISO 6722, QC/T 1037, ISO 19642-2019 |
|
XLPO (Silane Cross-linkable) |
XPS6000-105 |
Building wire insulation and jacketing |
JB / T 10436-2004 |
|
XLPO (Silane Cross-linkable) |
XPS6000-125 |
Building wire insulation and jacketing |
JB/T 10436-2004 |
|
XLPO (Silane Cross-linkable) |
XPS7901N |
Insulation and jacketing with oil resistance requirement |
EN 50264, EI1 01-109, EM 101-104 IEC 60092-359 SHF2, IEC 62893-1, EVM-2 |
|
XLPO (Silane Cross-linkable) |
XPS8051 |
105°C wiring cable, Extrusion conductor ≤6 mm2 CAT A / CAT B |
JB/T 10436-2004 |
|
XLPO (Silane Cross-linkable) |
XPS8052 |
105°C wiring cable, Extrusion conductor ≤6 mm2 CAT A / CAT B / CAT C |
JB/T 10436-2004 |
|
XLPO (Silane Cross-linkable) |
XPS8054 |
Insulation compound for B1 grade |
JB / T 10436-2004 |
|
XLPO (Silane Cross-linkable) |
XPS8251 |
125°C wiring cable, Extrusion conductor ≤6 mm2 CAT A / CAT B / CAT C |
JB/T 10436-2004 |
|
XLPO (Silane Cross-linkable) |
XPS8251E |
125℃ wiring cable, Squeeze tube conductor ≤6 mm2 CAT A / CAT B |
JB/T 10436-2004 |
|
XLPO (Silane Cross-linkable) |
XPS8252 |
125°C wiring cable, Extrusion conductor ≤6 mm2 CAT A / CAT B / CAT C |
JB / T 10436-2004 |
|
XLPO (Silane Cross-linkable) |
XPS8254 |
125℃ B1 grade FR wiring cable, ≥ 2.5mm2 |
JB/T 10436-2004 |
|
XLPO (Silane Cross-linkable) |
XPS8051G |
105°C external insulation of buliding wire with 70 years service life |
JG/T 441-2004, JG/T 442-2004 |
|
XLPO (Silane Cross-linkable) |
XPS8051GH |
105°C jacketing of buliding wire with 70 years service life |
JG/T 441-2004, JG/T 442-2004 |
|
XLPO (Silane Cross-linkable) |
XPS8251G |
125°C external insulation of buliding wire with 70 years service life |
JG/T 441-2004, JG/T 442-2004 |
|
XLPO (Silane Cross-linkable) |
XPS8251GH |
125°C jacketing of buliding wire with 70 years service life |
JG/T 441-2004, JG/T 442-2004 |
|
XLPO (Silane Cross-linkable) |
XPS8051H |
FR cable jacketing |
JB/T 10436-2004 |
|
XLPO (Silane Cross-linkable) |
XPS8052C |
105°C FR cable insulation |
JB/T 10436-2004 |
|
XLPO (Irradiation Cross-linkable) |
XPI10017-105 |
105°C LSOH FR, GB electronic wire, BV wire |
JB / T 10436-2004 |
|
XLPO (Irradiation Cross-linkable) |
XPI10017-125 |
125°C LSOH FR, Good FR, Less spark breakdown point |
/ |
|
XLPO (Irradiation Cross-linkable) |
XPI10017-150 |
150°C LSOH FR, Good heat resistance, High temp. non-adhesion |
/ |
|
XLPO (Irradiation Cross-linkable) |
XPI10017C(H) |
Marine cable jacketing |
IEC 60092-360 |
|
XLPO (Irradiation Cross-linkable) |
XPI10017C(J) |
Marine cable insulation |
IEC 60092-360 |
|
XLPO (Irradiation Cross-linkable) |
XPI10017D-125 |
125°C motor lead cable |
JB/T 6213-2006 |
|
XLPO (Irradiation Cross-linkable) |
XPI10017D-150 |
150°C motor lead cable |
JB/T 6213-2006 |
|
XLPO (Irradiation Cross-linkable) |
XPI10017QI-125 |
125°C EN automotive cable |
ISO 6722 C |
|
XLPO (Irradiation Cross-linkable) |
XPI10017QA-125 |
125°C JIS(JASO) automotive cable |
JASO D 611 |
|
XLPO (Irradiation Cross-linkable) |
XPI10017QE-125 |
125°C ANSI(SAE) automotive cable |
SAE J 1128 |
|
XLPO (Irradiation Cross-linkable) |
XPI10017S-150 |
150°C electric automotive high-voltage wire |
ISO 6722 C, QC/T 1037, K179 |
|
XLPO (Irradiation Cross-linkable) |
XPI10017-TB |
Iron standard locomotive cable, Oil resistance |
TB/T 1484.1-2010 |
|
XLPO (Irradiation Cross-linkable) |
XPI10017-GB |
GB locomotive cable, Oil resistance |
GB/T 12528-2008 |
|
XLPO (Irradiation Cross-linkable) |
XPI10017-EN |
EN locomotive cable, High oil resistance |
EN 50264 |
|
XLPO (Irradiation Cross-linkable) |
XPI10017-JC |
JIS locomotive cable, Elongation ≥360%, Oil resistance |
JIS C 3005 |
|
XLPO (Irradiation Cross-linkable) |
XPI10017-GE |
ANSI(GE) locomotive cable, High temp. oil resistance, low temp. resistance |
/ |
|
XLPO (Irradiation Cross-linkable) |
XPI10017U-105 |
UL 105°C electronic wire |
UL 3385, UL 3386 |
|
XLPO (Irradiation Cross-linkable) |
XPI10017U-125 |
UL 125°C electronic wire |
UL 3316, UL 3173 |
|
XLPO (Irradiation Cross-linkable) |
XPI10017U-150 |
UL 150°C electronic wire |
UL 3321, UL 3398 |
|
XLPO (Irradiation Cross-linkable) |
XPI10019S-125 |
125°C charging pile insulation, Heat resistance |
2 Pfg1908; CQC 1103-1105 |
|
XLPO (Irradiation Cross-linkable) |
XPI10026D-125 |
125°C German standard automotive cable |
/ |
|
XLPO (Irradiation Cross-linkable) |
XPI10026D-150 |
150°C German standard automotive cable |
/ |
|
XLPO (Irradiation Cross-linkable) |
XPI10027T-125 |
TUV photovoltaic cable |
2 Pfg1169, 2 Pfg990 |
|
XLPO (Irradiation Cross-linkable) |
XPI10027EN-125 |
EN photovoltaic cable |
EN 50618 |
|
XLPO (Irradiation Cross-linkable) |
XPI10027-125 |
TUV/EN double certification photovoltaic cable |
2 Pfg1169, 2 Pfg990, UL 4703 |
|
XLPO (Irradiation Cross-linkable) |
XPI-F2107 |
Oil resistance thermosetting jacketing compound for marine cable |
IEC60092-360 |
|